User Login Registration Password recovery
Email Username

Load cells

Load cells presently manufactured by AEP transducers are included in the requisites of OIML R60 regulations (International Organization of Legal Metrology) which establishes all the tests (temperature, moisture, barometric pressure, etc...) to be passed by the product in order to be included in certain precision classes C2, C3, C4 …
To ensure these requisites, AEP transducers has developed inside itself some direct-weight automatic equipment which were accredited by ACCREDIA in 1996 for model control according to this regulation.
Load cells are periodically checked by Metrological Laboratory personnel who performs constant tests on series production, with an always careful view to the product continuous improvement.
Thanks to technical staff know-how,all the procedures to perform model approval for legal uses are being activated by autorithies in control.

              

CLS

   

Load cell for the measurement of static and dynamic loads in COMPRESSION.
Nominal Load from 30t to 500t
Class (OIML R60) C1 and C2
Combined Error: 0,023%
Output: 2mV/V

CBS

   

Load cell for the measurement of static and dynamic loads in COMPRESSION.
Nominal Load from 250 kg to 100 tons
Combined Error: 0,03%
Output: 2mV/V
LOW COST version produced for over 30 years
       

C2S

   

Load cell for the measurement of static and dynamic loads in COMPRESSION
Nominal Load from 100 kg to 200 tons
Class (OIML R60) C1, C2 and C3
Combined Error: 0,023%
Output: 2mV/V
         On request 
  

C2S-AMP

   

Load cell for the measurement of static loads in COMPRESSION.
Nominal Load from 100 kg to 200 tons
linearity andhysteresis 0.03%


    

F1

   

BENDING BAEM load cell for the measurement of static and dynamic loads.
Nominal Load from 2,5 kg to 200 kg
Class (OIML R60) C2 and C3
Combined Error: 0,020%
Output: 2mV/V

F3

   

BENDING BAEM load cell for the measurement of static and dynamic loads
Nominal Load from 10 kg to 2 tons
Class (OIML R60) C2 and C3
Combined Error: 0,018%
Output: 2mV/V

FT1

   

SHEAR BEAM load cell for the measurement of static and dynamic loads
Nominal Load from 350 kg  to 7,5 tons
Class (OIML R60) C2 and C3
Combined Error: 0,020%
Output: 2mV/V

FT2

   

SHEAR BEAM load cell for the measurement of static and dynamic loads.
Nominal Load from 500 kg  to 10 tons
Class (OIML R60) C2 and C3
Combined Error: 0,019%
Output: 2mV/V

FT6

   

OFF CENTER load cell for the measurement of static and dynamic loads
Nominal Load from 5 kg to 100 kg
Class (OIML R60) C2
Combined Error: 0,028%
Output: 2mV/V

TCA

   

Load cell for the measurement of static and dynamic loads in COMPRESSION and TENSION
Nominal Load from 1 kg to 50 kg
Linearity and Hysteresis 0.03%
Output: 2mV/V

TS

   

Load cell for the measurement of static and dynamic loads in TENSION and COMPRESSION
Nominal Load from 10 kg to 10 tons
Class (OIML R60) C2, C3 and C4
Combined Error: 0,018%
Output: 2mV/V

TS-AMP

   

Load cell for the measurement of static and dynamic loads in TENSION and COMPRESSION
Nominal Load from 10 kg to 10 tons
linearity and hysteresis 0,030%
Standar output M12 connector

    

CLT

   

Load cell for the measurement of static and dynamic loads in TENSION and COMPRESSION
Nominal Load from 100 tons to 250 tons
Linearity: 0,10%
Output: 2mV/V
          on request
 

D200

   

Load cell for the measurement of static and dynamic loads in TENSION
Nominal Load from 20 tons to 100 tons
Linearity: 0,10%
Output: 2mV/V
         on request
 

T20

   

Load cell for the measurement of static and dynamic loads in TENSION
Nominal Load from 5 tons to 20 tons
Class (OIML R60) C2 and C3
Combined Error: 0,019%
Output: 2mV/V
           on request
 

T20-AMP

     

Load cell for the measurement of static loads in TENSION
Nominal Load from 5 tons to 20 tons
Linearity and Hysteresis 0.03%
Standar output M12 connector

    

TCE

   

Load cell for the measurement of static and dynamic loads in COMPRESSION and TENSION
Nominal Load from 350 kg to 20 tons
Linearity and Hysteresis 0.03%
Output: 2mV/V
         on request

TCE-AMP

   

Load cell for the measurement of static loads in COMPRESSION and TENSION
Nominal Load from 350 tons to 20 tons
Linearity and Hysteresis 0.03%
Standar output M12 connector

    

Leave a